Search results for "Dental Equipment"
showing 5 items of 5 documents
Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?
2011
Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samp…
Dental CBCT equipment and performance issues
2012
Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radio…
Italian multicenter study on infection hazards during dental practice: Control of environmental microbial contamination in public dental surgeries
2008
Abstract Background The present study assessed microbial contamination in Italian dental surgeries. Methods An evaluation of water, air and surface microbial contamination in 102 dental units was carried out in eight Italian cities. Results The findings showed water microbial contamination in all the dental surgeries; the proportion of water samples with microbial levels above those recommended decreased during working. With regard to Legionella spp., the proportion of positive samples was 33.3%. During work activity, the index of microbial air contamination (IMA) increased. The level of microbial accumulation on examined surfaces did not change over time. Conclusion These findings confirm …
Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and t…
2012
A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWS…
Noise levels in a dental teaching institute: a matter of concern!
2011
Objective: To measure and assess the noise levels produced by various dental equipments in different areas of a dental institution and to recommend improvements if noise levels are not within permissible limits. Material and Methods: Sound levels were measured at three different areas of a dental institution where learning and teaching activities are organized. The sound level was measured using a sound level meter known as ‘decibulolmeter’. In each area the noise level was assessed at two positions-one, at 6 inches from the operators ear and second, at the chairside instrument trolley. Noise levels were also assessed from a central location of the clinic area when multiple equipments were …